Uninterruptible Power Supplies
All UPS systems provide approximately 10 minutes of battery autonomy at full load unless otherwise noted. Please remember that battery time is not a linear factor: eg, a 6kVA/4.2kW rated unit will run a 4kW load for approximately 10 minutes or a 1kW load for approximately 1 hour. Battery time will also depend on the type & power factor of the load you are running. It will also be affected by equipment/ambient temperature.
| Single phase | ||
| Manufacturer | Voltage/Freq | Rating |
| EMERSON ACCUPOWER GOLD | 240V 50Hz | 1kVA/700W |
| 2.1kVA/1.5kW | ||
| EMERSON UGX RACK MOUNT OR TOWER |
220/240V 50Hz | 1.5kVA /1.05kW |
| 2.1kVA/1.5kW | ||
| EMERSON AP130 | 120/240V 50/60Hz | 3kVA/2.4kW |
| EMERSON AP200 SERIES | 220/240V 50Hz | 3kVA/2.1kW |
| 6kVA/4.2kW | ||
| 10kVA/7kW | ||
| LIEBERTEMERSON GXT: RACK MOUNT OR TOWER |
208/220/240V 50/60Hz | 0.7kVA/420W |
| 1.5kVA/1.05KW | ||
| 2.0kVA/1.4KW | ||
| 3.0kVA/2.1KW | ||
| 6.0kVA/4.2KW | ||
| EXIDE POWERWARE PLUS 6 | 200-240V 50/60Hz | 6kVA/4kW |
| POWERWAVE 2000 SERIES | 220-240v 50/60Hz | 6kVA/4.2KW |
Most of our smaller rack UPS sytems are now fitted with the Neutrix Power Con system for input and output connections.
Line Voltage Conditioners
| Passive | |||
| Manufacturer | Input | Output | Rating |
| CETRONICS REGUVOLT | 192-264V 50Hz |
240V |
1kVA, 3kVA, 4kVA, 5kVA, 7.5kVA, 10kVA |
| GALATREK 3000VA | 200-264V 50Hz | 240V Stability 3% |
3kVA |
| Electronic | |||
| CETRONICS EMPC | 192-264V 50/60Hz |
240V Stability 5% |
5kVA.7.5kVA |
Inverters
| Input | Output | Rating |
| 24V DC | 240V 50Hz | 1kVA |
| 48V DC | 240V 50Hz | 3kVA |
Frequency Changers
| Rotary | ||
| Input | Output | Rating |
| 3-phase 380-415V 50Hz | 110-120V 60Hz | 6kVA |
| 3-phase 380-415V 50Hz | 3-phase 208V 60Hz | 20kVA, 40kVA, 60kVA, 100kVA |
| Static | ||
| 120/220/240V 50Hz | 120/220/240V 60Hz | 1.2kVA, 2.4kVA |
Load Banks
40kVA
20kVA
Transformers
| Double-wound | ||
| Input | Output | Rating |
|
3-phase 190/200/208/380/400/415V 50/60Hz 3-phase 380/400/415V 50/60Hz 3-phase 190/200/208V 50/60Hz |
3-phase 190/200/208/380/400/415V 50/60Hz3-phase 190/200/208V 50/60Hz 3-phase 380/400/415V 50/60Hz
|
90kVA
22kVA, 75kVA, 90kVA, 150kVA
|
| 220/240V 50/60Hz | 110/120V 50/60Hz | 1kVA, 1.5kVA, 2kVA, 7.5kVA. 10kVA. 15kVA. 26kVA. 30kVA |
| 3-phase 415V Delt | 3-phase 415V Star | 15kVA, 20kVA |
| Auto-wound | ||
| 380/400/415/190 /200/208V - 50/60Hz |
380/400/415/190 /200/208V - 50/60Hz |
36kVA, 12kVA |
| 220/230/240/100 /110/115/120V - 50/60Hz |
220/230/240/100 /110/115/120V - 50/60Hz |
30kVA, 2kVA, 3kVA |
Variacs
| Input | Output | Rating |
| 415V 50/60Hz | 0-476V continuously variable | 25A and smaller |
| 42A and larger | ||
| 240V 50/60Hz | 0-264V continuously variable | 8A, 20A, 50A, 125A |
Distribution and Cable - CAMLOC & POWERLOCK
4 pole MCCB Thermal/Magnetic trip c/w variable RCD
Dual camloc outputs 400-160A
3 pole MCCB Thermal/Magnetic trip c/w variable RCD 400-160A
RCD protected Outputs 16A to 125A Ceeform
Cable: 35, 50, 70 ,120mm single core HO7RNF
Tails: 5M
Runs: 25M/50M
Distribution and Cable - CEEFORM
We offer a variety of Ceeform distro and cables to any specification with or without rcd protection. Full details on request.
Distribution
| Input | Output |
| 1-phase 16A | 4 or 6 x 13A graphic |
| 1-phase 32A | 6,8 or 10 x 13A graphic |
| 1-phase 63A | 6 x 16A front-back |
| 1-phase 63A | 6 x 13A graphic |
| 3-phase 63A | 3 x 1-phase 63A front-back |
Cable
3-phase: 32A, 63A, 125A
1-phase: 16A, 32A, 63A
Tails: 16A to 125A
Runs: 5M/10M/25M/50M/100M
Cable - EDISON US standard 3 pin
Edison cable run - 15A: 5M/10M/25M
Edison quad boxes: 5M/10M/25M
Edison 6 way strips, plugs and sockets
We are also stocking various ratings of portable RCD's both single and three phase. All units are supplied with up to date test certificates and instructions.
Hubbell TrukTrak Cable Protection Ramps
3ft in length with 5 31.8x31.8mm channels. Yellow Lid on Blue. Join together to form any length required. Supplied loose or on Pallets. Use wherever cable or pipework protection is required or trip hazards exist.
Power Analysis and Recording
Fluke VR101 Event Recorder detects and records voltage levels brownouts and transient events: sag, swell, surge and droop. It is a 13A type plug top device which is programed with test parameters from the laptop and then left on site. Later, the collected data can be downloaded through the optical interface and analysed at some other time. Data may also be printed in a report from the laptop.
PowerLogger 200 is a fully loaded single phase 230V disturbance analysis system, sampling at speeds fast enough to capture half-cycle events. Fully programmable through laptop, this device measures volts, amps, power, power factor, crest factor, harmonics and frequency. Can produce graphs of all measurements and is able to record several days-worth of data.
Lab Equipment and Power Supplies
A wide variety of lab equipment including DC and AC supplies is available but, as many are used in our tech facility, they are allocated on a job basis only when customers are unable to source suitable equipment eleswhere. Full details are available on request.